Select Group
Select Group
Group 11 Rotary Damper Drives & Actuators
Group 11 Quarter-Turn Rotary Actuators
Group 57 Rotary Valve Actuator
Group 22 Rotary Damper Drives
Group 75 Compact Rotary Actuators
Group 31 Quarter-Turn Compact Rotary Actuators
Group 42 Linear Actuators
Group 29 Linear Valve Actuators
Group 14 Linear Valve Actuators
Actuators
Accessories
Resources
Industries
About Us
Search by Model or Serial #
ico
Actuator Configuration Group 11
Configure
Voltage / Phase / Frequency
120 / 1 / 60*
240 / 1 / 60*
208 / 3 / 60*
380 / 3 / 60*
415 / 3 / 60*
480 / 3 / 60*
575 / 3 / 60*
*50 Hz available, Timing increases by 20%
Control Option
9 - (4-20 mA control/feedback - Digital with HART, LED's, pushbuttons)
9 - (FOUNDATION FIELDBUS)
9 - (PROFIBUS)
9 - (MODBUS RTU)
9 - (MODBUS TCP)
8 - (4-20 mA control/feedback - analog for legacy replacements)
7 - (4-20 mA control / no feedback)
6 - (Direct AC control / 4-20 mA feedback)
5 - (Direct AC control / potentiometer position)
4 - (Direct AC control - multi-position)
3 - (Direct AC open/close)
Auxiliary limit switches
None
2X SPDT
4X SPDT
Handswitch Options
Standard
Auxililary contact - Closed in AUTO
Auxililary contact - Open in AUTO
Lockable Handswitch
Model
11-150
11-200
11-300
11-400
11-430
11-160
11-260
11-360
11-460
Torque (lb-ft) / Timing (11-150)
15 / 11
20 / 20
40 / 20
40 / 40
60 / 60
80 / 24
80 / 40
80 / 90
120 / 40
Torque (lb-ft) / Timing (11-200)
125 / 20
125 / 40
175 / 60
250 / 24
250 / 40
250 / 75
Torque (lb-ft) / Timing (11-300)
300 / 24
300 / 40
300 / 100
400 / 36
400 / 60
550 / 45
550 / 75
650 / 60
650 /100
Torque (lb-ft) / Timing (11-400)
350 / 24
550 / 40
650 / 24
800 / 60
1000 / 24
1000 / 40
1000 / 75
1500 / 100
1800 / 36
1800 / 60
Torque (lb-ft) / Timing (11-430)
2900 / 72
2900 / 120
5200 / 108
5200 / 180
Torque (lb-ft) / Timing (11-160)
15 / 10
20 / 18
40 / 18
40 / 36
60 / 54
80 / 22
80 / 36
80 / 81
120 / 36
Torque (lb-ft) / Timing (11-260)
125 / 18
125 / 36
175 / 54
250 / 22
250 / 36
250 / 68
Torque (lb-ft) / Timing (11-260)
300 / 22
300 / 36
300 / 90
400 / 32
400 / 54
550 / 41
550 / 68
650 / 54
650 / 90
Torque (lb-ft) / Timing (11-460)
350 / 22
550 / 36
650 / 22
800 / 54
1000 / 22
1000 / 36
1000 / 68
1500 / 90
1800 / 32
1800 / 54
Linkage Kit (11-150)
No Selection
Hex (p/n 14-8300-22) 9"-11.5"
Hex (p/n 14-8300-32) 10.5"-14.5"
Hex (p/n 14-8300-04) 14.5"-18.5"
Hex (p/n 14-8300-06) 18"-22"
Hex (p/n 14-8300-16) 22"-26"
Pipe - 1" (p/n 20-1730-05 ) 22"-84"
Pipe - 1.5" (p/n 20-1740-06 ) 31"-120"
Linkage Kit (11-200)
No Selection
Hex (p/n 14-8300-22) 9"-11.5"
Hex (p/n 14-8300-32) 10.5"-14.5"
Hex (p/n 14-8300-04) 14.5"-18.5"
Hex (p/n 14-8300-06) 18"-22"
Hex (p/n 14-8300-16) 22"-26"
Pipe - 1" (p/n 20-1730-05 ) 22"-45"
Pipe - 1.5" (p/n 20-1740-06 ) 31"-84"
Pipe - 2" (p/n 20-1750-05 ) 33"- 120"
Pipe - 2.5" (p/n 20-1760-05 ) 37"-120"
Linkage Kit(11-400)
No Selection
Hex (p/n 15-0110-26) 13.5"-17.5"
Hex (p/n 15-0110-20) 18"-22"
Hex (p/n 15-0110-03) 22"-26"
Hex (p/n 15-0110-22) 26"-30"
Hex (p/n 15-0110-02) 29"-33"
Pipe - 1" (p/n 20-1730-07 ) 23"-34"
Pipe - 1.5" (p/n 20-1740-08 ) 32"-48"
Pipe - 2" (p/n 20-1750-07 ) 34.5"- 72"
Pipe - 2.5" (p/n 20-1760-07 ) 38"-120"
Linkage Kit(11-430)
No Selection
Pipe - 2" (p/n 20-1760-13 ) 23.5"- 40"
Pipe - 3" (p/n 20-1760-10 ) 38"- 144"
Pipe - 3" (p/n 20-1760-09 *) 60"- 144"
*use when angle between linkage and crank arm is less than 25 degrees
Linkage Kit(11-300)
No Selection
Hex (p/n 14-8860-24) 13.5"-18"
Hex (p/n 14-8860-08) 17.5"-22"
Hex (p/n 14-8860-02) 22"-26.5"
Hex (p/n 14-8860-04) 26.5"-31"
Pipe - 1" (p/n 20-1730-06 ) 22.5"-36"
Pipe - 1.5" (p/n 20-1740-07 ) 31.5"-72"
Pipe - 2" (p/n 20-1750-06 ) 34"- 96"
Pipe - 2.5" (p/n 20-1760-06 ) 37.5"-120"
Options
Pedestal
Hazardous Locations Rating
Backup Power Unit
Remote Mount Electronics
Digital Feedback Display
Remote indicating control station
DPDT relay
Torque Sensing
Thermal Barrier
Lockable Handswitch
Stainless Steel Tagging
Options
Pedestal
Hazardous Locations Rating
Backup Power Unit
Remote indicating control station
DPDT relay
Thermal Barrier
Lockable Handswitch
Stainless Steel Tagging
Valve Size
Valve Make
Valve Model
Name
*
Phone
Email
*
Company
End User
Application
Δ